Jiangsu Profile
Famous Export Brand
Featured Products
Product List
61. Sidc16-12 Solid Insulated Ring Network Cabinet for High-Rise Building [Apr 19, 2024]
12KV Small Size Solid Insulated Switchgear Product specification: Load switchgear parameters No Item Unit Parameter 1 Type of interrupter Vacuum 2 Rated current A 630 3 Rated short time withstand ...
62. Sidc16-12 Solid Insulated Ring Network Cabinet for Shopping Mall Green Environment [Apr 19, 2024]
12KV Small Size Solid Insulated Switchgear Product specification: Load switchgear parameters No Item Unit Parameter 1 Type of interrupter Vacuum 2 Rated current A 630 3 Rated short time withstand ...
63. Sidc16-12 Solid Insulated Ring Network Cabinet for Wind Power Station [Apr 17, 2024]
12KV Small Size Solid Insulated Switchgear Product specification: Load switchgear parameters No Item Unit Parameter 1 Type of interrupter Vacuum 2 Rated current A 630 3 Rated short time withstand ...
64. Sidc16-12 Solid Insulated Ring Network Cabinet for Subway for Open Coal Mining [Apr 17, 2024]
12KV Small Size Solid Insulated Switchgear Product specification: Load switchgear parameters No Item Unit Parameter 1 Type of interrupter Vacuum 2 Rated current A 630 3 Rated short time withstand ...
65. 50Hz 12kv Solid Insulated Switchgear [Apr 07, 2024]
50HZ 12KV Solid Insulated Switchgear Product Specification: Load switchgear parameters No Item Unit Parameter 1 Type of interrupter Vacuum 2 Rated current A 630 3 Rated short time withstand ...
66. 12kv Small Size Solid Insulated Switchgear [Apr 06, 2024]
12KV Small Size Solid Insulated Switchgear Product specification: Load switchgear parameters No Item Unit Parameter 1 Type of interrupter Vacuum 2 Rated current A 630 3 Rated short time withstand ...
67. Ybm-10/0.4 Pre-Fabricated Substation for Oil Field [Apr 29, 2024]
TECHNICAL SPECIFICATION Item Unit Parameter Rated voltage KV 12/0.4 24/0.4 Rated short-time power frequency withstand voltage(phase/fracture) KV/1 min 42/48 42/48 Rated lighting impulse withstand ...
68. Ybm-10/0.4 Pre-Fabricated Substation for Railway [Apr 27, 2024]
TECHNICAL SPECIFICATION Item Unit Parameter Rated voltage KV 12/0.4 24/0.4 Rated short-time power frequency withstand voltage(phase/fracture) KV/1 min 42/48 42/48 Rated lighting impulse withstand ...
69. Power Distribution Substation for Parks [Apr 27, 2024]
Technical Specification: Item Unit Parameter Rated voltage KV 12/0.4 24/0.4 Rated short-time power frequency withstand voltage(phase/fracture) KV/1 min 42/48 42/48 Rated lighting impulse withstand ...
70. Power Distribution Substation for Shopping Malls [Apr 27, 2024]
Technical Specification: Item Unit Parameter Rated voltage KV 12/0.4 24/0.4 Rated short-time power frequency withstand voltage(phase/fracture) KV/1 min 42/48 42/48 Rated lighting impulse withstand ...
71. Three Phase Power Distribution Substation [Apr 26, 2024]
TECHNICAL SPECIFICATION Item Unit Parameter Rated voltage KV 12/0.4 24/0.4 Rated short-time power frequency withstand voltage(phase/fracture) KV/1 min 42/48 42/48 Rated lighting impulse withstand ...
72. Sidc16-12 Solid Insulated Ring Network Cabinet for Hotel Green Environment [Apr 26, 2024]
12KV Small Size Solid Insulated Switchgear Product specification: Load switchgear parameters No Item Unit Parameter 1 Type of interrupter Vacuum 2 Rated current A 630 3 Rated short time withstand ...
73. Small Size Solid Insulated Switchgear with Sf6 Gas [Apr 13, 2024]
Small Size Solid Insulated Switchgear With SF6 Gas Product specification: Load switchgear parameters No Item Unit Parameter 1 Type of interrupter Vacuum 2 Rated current A 630 3 Rated short time ...
74. Pre-Fabricated Substation for Residential Areas [Apr 30, 2024]
Technical Specification: Item Unit Parameter Rated voltage KV 12/0.4 24/0.4 Rated short-time power frequency withstand voltage(phase/fracture) KV/1 min 42/48 42/48 Rated lighting impulse withstand ...
75. OEM Outdoor Three Phase Power Distribution Substation [Apr 26, 2024]
TECHNICAL SPECIFICATION Item Unit Parameter Rated voltage KV 12/0.4 24/0.4 Rated short-time power frequency withstand voltage(phase/fracture) KV/1 min 42/48 42/48 Rated lighting impulse withstand ...